MISSISSIPPI SHIPBUILDER SAVES TIME AND MONEY PERFORMING DESIGN
OPTIMIZATION AND SHOCK TESTING WITH FEA SOFTWARE
|
Ingalls Shipbuilding developed a new quick-acting, watertight
door for military ships that is lighter, less detectable by enemy
radar, requires less maintenance and has a more advanced sealing
mechanism than existing doors. The company performed a virtual
shock test using Mechanical Event Simulation from ALGOR, Inc.
to ensure that the door withstands U.S. Navy shock requirements. |
October 23, 1998, Pittsburgh, Pennsylvania -- The United
States Navy requires ships that can endure dangerous conditions
like severe weather, a missile attack or a mine explosion. Ship
components are tested for water pressure and shock endurance prior
to installation to ensure that they can withstand such threatening
conditions.
Ingalls Shipbuilding division of Litton Industries in Pascagoula,
Mississippi has designed and manufactured 76 of the U.S. Navy's
339 active ships and modernized dozens of its surface combatant
ships. The company recently developed a new quick-acting, watertight
door for military use and used linear stress analysis and Mechanical
Event Simulation software from ALGOR, Inc. to optimize the design
to meet the U.S. Navy's water pressure requirement. It then used
ALGOR's Mechanical Event Simulation software to simulate a shock
test of the door. The computer analyses avoided expensive and
time-consuming prototype testing in a laboratory and ensured that
the new watertight door withstands the military's water pressure
and shock requirements.
Military Interest in More Efficient,
Inconspicuous, Watertight Doors
Over one hundred watertight doors are located both within a
ship and on a ship's exterior in direct contact with weather and
wave splash. They must close securely and form a watertight seal
to guard the ship's compartments from being consumed by water
if damage causes a leak. They are also used to block the spread
of noxious fumes and stall spreading fires. The staff of the Carnival
Cruise ship that caught fire on July 20, 1998 as it set sail for
Key West, Florida and Cozumel, Mexico closed the ship's rear watertight
doors to seal the compartments and delay the fire from spreading
forward from the stern.
Ingalls Shipbuilding's new quick-acting, watertight ship door
has many advantages over current watertight ship doors that would
be attractive to the military. It is lighter, requires less maintenance,
has a more advanced sealing mechanism and is less detectable by
enemy radar.
The door has a longer life than traditional carbon steel watertight
doors because it has an organic e-glass/vinyl-ester surface that
is corrosion and rust resistant. Its balsa wood and fiberglass
composite door panel reduced its weight by nearly 50% because
it is lighter than carbon steel. The door's weight was reduced
because a lighter door is easier to control.
The new door has bulkhead support built into its frame. The
bulkhead is the ship's interior wall that separates compartments.
When turbulent waters cause the ship's decks to move in opposite
directions, the bulkhead experiences shearing loads that concentrate
around the doors. Existing doors distort and then fail prematurely
as a result of shearing loads, causing the bulkhead to experience
plastic deformation. Ingalls Shipbuilding's door now has a stiff
ring of material around its frame that absorbs the shearing load
path to reinforce the door. This bulkhead support is also intended
to reduce the rework needed after the door is assembled in the
ship and the ship is transported to the dry dock by rail car and
lowered into the water. Shipbuilders do not design for the damaging
effects of the door's assembly and transportation because it is
difficult to define the loads in such conditions. It is also more
costly to develop features not applicable to the door's intended
use than to rework the doors after their assembly and transportation.
The door has a metal, corrosion-resistant sealing mechanism
with six to eight latches that open and close the door, forming
a watertight seal, with the single motion of a handle turned in
a 180-degree arc. The innovative sealing mechanism functions easier,
has a longer life, and requires less maintenance than existing
watertight doors. Its seal is stronger because its soft, spongy,
neoprene gasket at the edge of the door frame compresses against
the bulkhead, like a refrigerator, rather than against a metal
knife edge.
Furthermore, the door was designed without "top side clutter,"
raised structures or surfaces on exterior doors that could be
easily detected by radar. It is possible for enemies to identify
the geography of a ship by locating top side clutter. In an effort
to make the new watertight door inconspicuous, Ingalls Shipbuilding
placed the door's closing mechanism within its frame, rather than
on the door's exterior like existing doors' closing mechanisms.
Linear and Nonlinear Stress Analysis
Software Used to Optimize Door's Geometry
Ingalls Shipbuilding had to determine if the new door could
withstand the U.S. Navy's water pressure endurance standard that
ensures the door's functionality in intense water pressure conditions.
In the laboratory water pressure test, or "hydrostatic"
test, conducted at Ingalls Shipbuilding, the door is installed
in a tank filled with enough water to produce the U.S. Navy's
required water pressure level, then removed and mounted on a test
wall to determine if it opens and closes as designed. Each laboratory
hydrostatic test can cost $3,000. To reduce costs, Ingalls Shipbuilding
used ALGOR's linear and nonlinear stress analysis software to
test and optimize the door's design under pressure loading on
the computer.
Engineers at Ingalls Shipbuilding designed a model of the door
in AutoCAD and used ALGOR's Houdini program to convert it
to a 3-D solid brick finite element model. Then they added a 3-D
solid brick model of the sealing mechanism to the door model.
|
An AutoCAD image of the watertight door. |
The sealing mechanism was created by Hartwell Corporation in
Placentia, California who used ALGOR's linear static stress analysis
software to test its strength and geometric design under loading
conditions required by the U.S. Navy before presenting it to Ingalls
Shipbuilding for analysis with the entire door. For example, its
engineering team applied given force loads to the handle that
were meant to represent the door being opened, closed and experiencing
abuse when pushed or pulled farther than necessary.
After assembling the door and sealing mechanism models, Ingalls
Shipbuilding used ALGOR's linear stress analysis composite processor
to analyze the strength of the door's inner balsa wood and fiberglass
layers under pressure that represented the U.S. Navy's standard
for water pressure endurance. (Later in the nonlinear analyses,
the collective properties of this sandwich composite were used
for the door's material properties.) Unexpectedly, the linear
hydrostatic analysis revealed excessive stress on the door's composite
surface that would cause cracking and peeling.
To uncover specific deflections in the door under varying pressure
loads over time, engineers turned to ALGOR's Accupak/VE Mechanical
Event Simulation for Virtual Prototyping with Linear and Nonlinear
Analysis. The nonlinear analysis indicated excessive stress and
deflection in the core portion of the door panel. The panel required
more flexibility so engineers reduced its thickness. Once the
door was optimized, engineers turned again to ALGOR's Accupak/VE
to perform a virtual shock test.
Mechanical Event Simulation Chosen
to Perform Virtual Shock Test
Military ship doors, along with all ship components, must withstand
shock, the intense vibration caused by the accelerated movement
of a ship responding to a severe disturbance like a storm, mine
explosion or missile launch. Ingalls Shipbuilding had to verify
that the optimized watertight door would operate after experiencing
shock levels specified by the U.S. Navy. Its sealing mechanism
must function after shock in order for it to close properly. The
door's shape must remain undistorted to guarantee a watertight
seal.
Prior to using Mechanical Event Simulation software, Ingalls
Shipbuilding sent military ship component prototypes to a laboratory
to test them on a shock table before building final prototypes
to test on a real ship. During the laboratory test, a large weight
is suspended above the shock table on which the test component
rests. It is dropped onto the shock table and the table's resulting
vibration causes the component to bounce. The weight is dropped
from a distance calculated to accelerate the shock table at a
rate that will cause the component to vibrate at its required
shock absorption level. Following this physical event, the component's
remaining functionality is physically analyzed. Laboratory technicians
mount the door on a test wall and determine if it opens and closes
as designed.
 |
|
Ingalls Shipbuilding performed a virtual shock
table test using ALGOR's Mechanical Event Simulation software.
In Image One, the weight (top right block) is dropped onto the
table a distance corresponding to the component's required shock
absorption. In Image Two, the weight has contacted the table
(bottom L-shaped object) and the impact caused it to bounce.
The resulting shock, or severe vibration, from the weight's initial
impact reverberates to the component, causing it to bounce on
the table. In Image Three, the weight has contacted the table
a second time as the component continues its ascent. Ingalls
Shipbuilding studies the component's stress results from the
initial impact. If the component withstands the shock vibration
of the initial impact, a force that represents the maximum acceleration
force from a ship's thrusting movement, it inherently withstands
subsequent shock vibrations. |
Each laboratory shock test costs between $5,000 and $15,000, can
take up to two weeks and often leads to further design improvements
and additional laboratory shock tests of the component. To cut
costs and save time, Ingalls Shipbuilding decided to replicate
the shock table test on the computer with ALGOR's Accupak/VE Mechanical
Event Simulation for Virtual Prototyping with Linear and Nonlinear
Stress Analysis.
Mechanical Event Simulation expands upon traditional finite
element analysis (FEA) because it includes physics and considers
time, motion and impact. Mechanical Event Simulation provides
a visual simulation of the entire real-world event. Further, in
a shock test, it is difficult to define input loads required for
traditional FEA. But Mechanical Event Simulation does not require
engineers to define input loads because they are defined by the
physics operating during the event.
In preparation for the virtual shock test, Ingalls Shipbuilding
performed a modal analysis to determine the door's natural frequency.
The Mechanical Event Simulation's timestep was set to one-tenth
of the natural period to ensure that the shock vibrations would
not occur at the door's natural frequency. A small timestep was
needed to analyze all responses during the event's evolution.
Engineers inserted contact elements in the model between the
table and the weight being dropped, and between the table and
the door to analyze their interaction. They also placed contact
elements between the floor and the table to prevent the floor's
damping effect. These contact elements simulated springs that
are placed between the floor and the table in the actual laboratory
test.
Virtual Shock Test Results
The virtual shock table test performed with ALGOR's Accupak/VE
software was identical to the laboratory test. In the computer
analysis, engineers specified the direction of gravity and dropped
a weight onto the table a distance that correlated to the U.S.
Navy guideline for shock endurance.
The weight dropped onto the table, and the reverberating shock
produced stress in the door. Mechanical Event Simulation calculated
stresses in the door over time caused by the dropped weight. Engineers
compared the stress values to the material properties' yield values.
As in the physical test, the effect of the initial bounce was
the only concern because it represents the maximum acceleration
force from a ship's thrusting movement. If the component withstands
the initial shock vibration, it theoretically could withstand
any remaining vibrations.
Ingalls Shipbuilding simulated one laboratory shock table test
using ALGOR's Accupak/VE software and detected no catastrophic
deflection in the door or any of its components, indicating that
the door would not fail when subjected to real-world conditions.
Watertight Door Prototypes to be Tested
on Military Ships
A physical laboratory test to confirm ALGOR's results has not
yet been conducted, but six prototypes of the final door are scheduled
for installation on two military ships and will be tested for
six to twelve months. If the U.S. Navy is satisfied with the door's
performance, Ingalls Shipbuilding intends to negotiate the installation
of the doors on new military ships as well as on ships already
operating in the U.S. Navy's fleet.
Ingalls Shipbuilding determined that analyzing the door on
the computer saved the company months of time and thousands of
dollars it would have taken to test several prototype doors in
a laboratory.
|
Six prototypes of the watertight door analyzed with ALGOR
software are scheduled for installation on two military ships
and will be tested for six to twelve months. If the U.S. Navy
is satisfied with the door's performance, Ingalls Shipbuilding
intends to negotiate the installation of the doors on military
ships like this guided missile destroyer, the USS McFaul (DDG
74,) which the company built and the U.S. Navy commissioned in
April 1998. |
|